imported>Deantwo |
imported>Kingofkosmos |
Line 127: |
Line 127: |
| |image = AirAlarm.png | | |image = AirAlarm.png |
| |foundin = Every room with atmospherics | | |foundin = Every room with atmospherics |
| |usedfor = Sniffing the atmospheric status near it and controlling the room's vents and scrubbers | | |usedfor = Sniffing the atmospheric status near it, sending alerts if something isn't right and controlling the room's vents and scrubbers |
| |strategy = Install it in a room wall and it'll find the vents and scrubbers in the room automatically.<br>See a more [[Guide to Atmospherics#Using an Air Alarm|in-depth guide how to use one here]] | | |strategy = Install it in a room wall and it'll find the vents and scrubbers in the room automatically |
| |description = The air regulator. Manages the vents and scrubbers. Gives out an alarm if there's toxins/temperature extremes/pressure extremes.
| | |description = To use an Air Alarm, first swipe your ID across it to unlock it. There are multiple options: |
| | |
| | '''Activate Atmospheric Alarm''': Self Explanatory. The Alarm will show on the Atmos Alert Computers and alerts the AI. |
| | |
| | '''Scrubbers Control''': Controls the scrubbers in the area. Select specific gases to be filtered. Choose between two settings for the scrubbers, scrubbing and syphoning. |
| | * Scrubbing will slowly drain any gases set to filter in the air of the tile they are on, and transfer it to their pipe. Really, really slow with N2O. |
| | * Syphoning will do the same, except indiscriminately and drain all gases on their tile. |
| | |
| | '''Vents Control''': you control vents through the air alarm. There are the following settings: |
| | * '''''External on''', Internal off'': will drain/add air from the tile the vent is on to make it reach the selected pressure. All air being moved goes into/comes out of the pipe the vent is attached to. Set to 0 to drain air, or pressurise to specific levels. |
| | *'''''Both on''''': completely useless. Don't bother. |
| | * ''External off, '''Internal on''''': Drains/adds air to the tile to get the pipe attached to the selected pressure level. Setting a vent to internal and the desired pressure to 0 causes ALL gas which enters the pipe to be shunted out onto the tile. |
| | |
| | '''Set Environmentals Mode''': you can select a preset mode for the scrubbers and vents in the area: |
| | * '''''Filtering''''': Default mode, scrubbers are set to "Filter", vents are set to keep the area at normal pressure (101kPa). |
| | * '''''Draught''''': scrubbers are set to "Syphon" and vents are On. |
| | * '''''Panic''''': scrubbers are set to "Panic Syphon" and vents are Off. |
| | * '''''Replace air''''': scrubbers are set to "Syphon" and vents are Off. Nearly identical to "Panic". |
| | * '''''Off''''': Both scrubbers and vents are Off. |
| | |
| | '''Sensor Settings''': Let's you change the minima and maxima for pressure, temperature and specific gases to automatically activate the alarm. |
| | |
| | '''Activate Panic Syphons''': They turn all vents off and set all scrubbers to syphon. You *can* do better than that, but most of the methods involve setting vents to suck, and if you need a panic syphon, then sucking contaminated air into Distro kinda sucks. |
| }} | | }} |
|
| |
|