User:Amwhah/Sandbox: Difference between revisions

From BeeStation Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 11: Line 11:
====Volume Pump====
====Volume Pump====
The volume pump is similar to the pressure pump, but operates differently. It has a pressure limit of 9000 kPa. However, this limit only kicks in when the output pipenet is currently over 9000 kPa. The pump will work if the output pipenet is below 9000 kPa, even if the resulting pressure of this action would be way higher than 9000 kPa. Counter to the pressure pump, this pump works on a L/s basis. This has a 2x200L volume as well, so you pick how much of the volume in the pump is actually pumped to the other side by changing the number. Because its max speed is 200 L/s, it will always outpace and outpressure the pressure pump. Can be overclocked using a multitool, which will cause its pressure limit to be dependent on the input pipenet, which will tend to make the maximum output pressure higher. However, this will cause 10% of gas running through it to spill.
The volume pump is similar to the pressure pump, but operates differently. It has a pressure limit of 9000 kPa. However, this limit only kicks in when the output pipenet is currently over 9000 kPa. The pump will work if the output pipenet is below 9000 kPa, even if the resulting pressure of this action would be way higher than 9000 kPa. Counter to the pressure pump, this pump works on a L/s basis. This has a 2x200L volume as well, so you pick how much of the volume in the pump is actually pumped to the other side by changing the number. Because its max speed is 200 L/s, it will always outpace and outpressure the pressure pump. Can be overclocked using a multitool, which will cause its pressure limit to be dependent on the input pipenet, which will tend to make the maximum output pressure higher. However, this will cause 10% of gas running through it to spill.
==== Volume Pump ====
The Temperature pump
====Passive Pump/Gate====
====Passive Pump/Gate====
These are a combination of pumps and valves. They work up to their set pressure, with a maximum of 100 atm. These can never do more than equalize the two connected pipenets, just as valves do. However, they only work one way, rather than mixing the gas between the two pipenets perfectly as valves do. Think of them as a pressure pump that only equalizes pressure between two pipenets.
These are a combination of pumps and valves. They work up to their set pressure, with a maximum of 100 atm. These can never do more than equalize the two connected pipenets, just as valves do. However, they only work one way, rather than mixing the gas between the two pipenets perfectly as valves do. Think of them as a pressure pump that only equalizes pressure between two pipenets.

Revision as of 10:25, 11 October 2022

The Atmos Devices

This will be a section detailing the overall function, and some specifics, of the various pipes, pumps, and other devices. Some details will be missed, but it will provide a basis. The first instance of a device running into a unique mechanic will be explained in further length.

Digital Valve

A valve that opens when clicked, and connects the two pipenets it separates when doing so. Counter to pumps, it experiences no delay in its gas transfer. It essentially acts as a pipe. Has 200L of volume on one side, and 200L on the other end. This can be operated by both carbon mobs such as humans, excluding xenomorphs, and silicons.

Pressure Valve

An activatable valve that lets gas pass through if the pressure on the input side is higher than the set pressure.

Manual Valve

Acts identically to a Digital Valve, however, the manual valve does not allow silicons to operate it.

Pressure Pump

An oddball case. Like all pumps, it separates connected pipenets if there is nothing else connecting them. Has a maximum pressure of 4500 kPa. All pumps work by pumping the contents within them to the other side, which is 200L on one side, and 200L on the other. Any pump can not pump gas that is not actually in it, which means that very large connected pipenets will have lower pump speeds. Pressure pumps work by gradually building up to its set pressure per tick. Because of this, pressure pumps slow down when approaching their target pressure, and will not quite match their pressure after a very long time, but will get very close.

Volume Pump

The volume pump is similar to the pressure pump, but operates differently. It has a pressure limit of 9000 kPa. However, this limit only kicks in when the output pipenet is currently over 9000 kPa. The pump will work if the output pipenet is below 9000 kPa, even if the resulting pressure of this action would be way higher than 9000 kPa. Counter to the pressure pump, this pump works on a L/s basis. This has a 2x200L volume as well, so you pick how much of the volume in the pump is actually pumped to the other side by changing the number. Because its max speed is 200 L/s, it will always outpace and outpressure the pressure pump. Can be overclocked using a multitool, which will cause its pressure limit to be dependent on the input pipenet, which will tend to make the maximum output pressure higher. However, this will cause 10% of gas running through it to spill.

Passive Pump/Gate

These are a combination of pumps and valves. They work up to their set pressure, with a maximum of 100 atm. These can never do more than equalize the two connected pipenets, just as valves do. However, they only work one way, rather than mixing the gas between the two pipenets perfectly as valves do. Think of them as a pressure pump that only equalizes pressure between two pipenets.

Unary Vent

The vent will pump gas into the room it is in, depending on the air alarm settings of the room. The air alarm has two settings to worry about, External, or Internal. External works by making the vent pump gas from its connected pipenet into the room until the room, or more accurately, the tile, matches the pressure that is set. The max pressure you can configure for External is 5066 kPa, and it slows down when approaching the set limit, as pressure pumps do. Internal works by pumping gas into the room from the pipenet until the pressure set matches the pressure in the connected pipenet. Examples: a vent set to External 200 will pump gas into the room until it is 200 kPa. A vent set to Internal 300 will pump gas into the room until the connected pipenet's pressure is 300 kPa, regardless of room pressure. As such, Internal 0 will always pump at full strength. This same effect can be achieved by turning off both External and Internal. The vent has a maximum speed it can pump at, even when extremely pressurised.

Passive Vent

An unpowered vent that equalizes the internal and external gases. Think of it as a simple open ended pipe into the atmosphere. It is not interactable and cannot be closed. It too, is not restricted by pressure as with the other vents, opening possibilities for interesting shenanigans.

Injector

The injector is similar to the vent in that it pumps gas onto the tile it is on. However, it is not controlled by an air alarm, but rather works by hand. It is also in L/s units again, similarly to the volume pump. Also similarly to the volume pump, it is the faster one when compared to its pressure based cousin, the vent. It does not have a maximum pressure change per second, as vents do, and will always outpace them. This comes at the cost of the control that vents give you.

Scrubber

The gas sucking cousin of the vent, which sucks gas into the connected pipenet. Scrubbers are operated using the connected air alarm. They only suck in gas that is on their tile, unless you set their range to Expanded, in which case it'll suck in a 3x3. Setting them to Siphon will make them suck in every gas. If the scrubber is not on siphon, you can select specific gases for it to suck into its pipenet. The more gases are selected to scrub, the more power is used.

Heat Exchanger

Place two of these next to each other, facing each other, and they will equalize the temperature of the gases inside them. The heat exchanger is not part of the (more widely used) heat exchange pipes system.

Temperature Pump

A pump that transfers energy in one direction until both sides are of equal temperature.

Temperature Gate

A valve that releases gas through if it is hotter/colder depending on its setting. Setting can be changed by using a multitool on it.

Filter

The filter is the first device that connects 3 pipenets. It can be set to a single gas, and it will dump this gas to the side it is pointing in. All gas that is not selected will continue straight forward, as the arrow is pointing in a single line. When set to Nothing, it will allow all gas through the straight path. The filter works in L/s, and as such does not experience pressure related slowdowns, however, it has a pressure maximum of 4500 kPa. When EITHER OUTPUT SIDE is 4500 kPa or above, the filter will not function, not allowing any gas to pas. That is, both in a straight line and on its offshoot, the pressure must be less than 4500 kPa.

Mixer

The mixer also requires 3 connections to function, as the filter does. The mixer will mix the two incoming gases using the ratio the user inputs, starts off at 50/50. Node 1 is the input in a straight line with the output, Node 2 is the offshoot compared to the output. Both inputs need to have gas in them to function unless a side with gas in it is set to 100%, in which case it will function and purely let that side through. Is pressure based, with the associated properties. Also has a pressure maximum of 4500 kPa. The mixing is influenced by temperature following the ideal gas law. When one of the input sides is hotter compared to the other input, it will let less of this side's gas through, mole-wise. This will give you scuffed ratios if you do not equalize temperatures, if you need the precision, make sure they're equal.

Heat Exchange pipes

Functions like regular pipe, however, this will attempt to equalize the temperature between the pipenet and the space it is in. This is based on heat capacity, which can be found on this page. Higher heat capacity means a gas will soak in more energy, which means it is better at cooling when cold, and better at heating when hot. These pipes commonly see use in Supermatter setups, to cool down the coolant by using these pipes in space. However, they can also be used to heat up places, of course. Has a 1K efficiency loss. Space is 2.7K, but heat exchange pipes will only cool the gas in them to be about 3.7K.

Heat Exchange Junction

These are used to transfer from normal pipes to heat exchange pipes. These need to be between a pipe, or pump, etc. and heat exchange pipes for gas to actually be transferred between the two different kinds of pipe. While this pipe looks partially like a heat exchange pipe, it does not equalize temperature in the way that heat exchanging pipes do. It only looks like it does, so these can be safely connected to any pipe in a normal room without risk.

Layer Adapter

Connects the 5 different layers of pipenets. For most stations, the red scrubber network will be on layer 2 while the blue air supply pipes will be on layer 4. Default layer is 3. Pipes on different layers do not interact with one another.